C-Netz: Work on system informations, metering and call queues

- Make system informations configurable
- Simulate call mertering
- Support for call queues on busy voice channels
This commit is contained in:
Andreas Eversberg committed 2017-09-01 18:42:51 +02:00
1 parent 3bfba37fff
commit dfdad21e3f
11 files changed
+573 -192

No files matched your search

+2 -2
View File
@@ -311,7 +311,7 @@ dsp.c:218 notice : Clock: RX=19.44 TX=19.49; Signal: RX=19.35 TX=19.43 ppm
<p>
One can see that the measured clock from the sound card (sample rate) differs about +19.45 PPM.
Because I did not do any correction to the signal processing, the same error applies to the signal processing.
Use command line option '-S 19.45,19.45' or '--clock-speed 19.45,19.45' to compensate the clock error by adjusting the signal processor.
Use command line option '-C 19.45,19.45' or '--clock-speed 19.45,19.45' to compensate the clock error by adjusting the signal processor.
Let it run again for one hour and you will see that clock deviation of the signal is below 1 PPM.
</p>
@@ -384,7 +384,7 @@ To run the base station I the following command line options:
<pre>
# cnetz -k 131 -p -d -S 19.25,19.25
# cnetz -k 131 -p -d -C 19.25,19.25
...
cnetz.c:142 notice : You selected channel 131 ('Orga-Kanal') for combined callin
g + traffic channel. Some phones will reject this.