fix bug when climate entity is using default min/max temp and temp unit is F
The default min/max temps are in C but when the climate entity is set up with F this will cause incorrect boundary check and an inability to change the temperature from the home assistant entity UI widget.
This commit is contained in:
@@ -343,6 +343,10 @@ class LocaltuyaClimate(LocalTuyaEntity, ClimateEntity):
|
||||
"""Return the minimum temperature."""
|
||||
if self.has_config(CONF_MIN_TEMP_DP):
|
||||
return self.dps_conf(CONF_MIN_TEMP_DP)
|
||||
# DEFAULT_MIN_TEMP is in C
|
||||
if self.temperature_unit == TEMP_FAHRENHEIT:
|
||||
return DEFAULT_MIN_TEMP * 1.8 + 32
|
||||
else:
|
||||
return DEFAULT_MIN_TEMP
|
||||
|
||||
@property
|
||||
@@ -350,6 +354,10 @@ class LocaltuyaClimate(LocalTuyaEntity, ClimateEntity):
|
||||
"""Return the maximum temperature."""
|
||||
if self.has_config(CONF_MAX_TEMP_DP):
|
||||
return self.dps_conf(CONF_MAX_TEMP_DP)
|
||||
# DEFAULT_MAX_TEMP is in C
|
||||
if self.temperature_unit == TEMP_FAHRENHEIT:
|
||||
return DEFAULT_MAX_TEMP * 1.8 + 32
|
||||
else:
|
||||
return DEFAULT_MAX_TEMP
|
||||
|
||||
def status_updated(self):
|
||||
|
Reference in New Issue
Block a user